[Top] [Contents] [Index] [ ? ]

Units: A Unit Conversion Program


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

1. Overview of units

The units program converts quantities expressed in various scales to their equivalents in other scales. The units program can handle multiplicative scale changes as well as nonlinear conversions such as Fahrenheit to Celsius.(1) Temperature conversions require a special syntax. See Temperature Conversion Example.

The units are defined in an external data file. You can use the extensive data file that comes with this program, or you can provide your own data file to suit your needs.

You can use the program interactively with prompts, or you can use it from the command line.


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

2. Interacting with units

To invoke units for interactive use, type units at your shell prompt. The program will print something like this:

 
    2131 units, 53 prefixes, 24 nonlinear units
    
    You have:

At the ‘You have:’ prompt, type the quantity and units that you are converting from. For example, if you want to convert ten meters to feet, type 10 meters. Next, units will print ‘You want:’. You should type the type of units you want to convert to. To convert to feet, you would type feet. Note that if the readline library was compiled in then the tab key can be used to complete unit names. See section Readline support, for more information about readline.

The answer will be displayed in two ways. The first line of output, which is marked with a ‘*’ to indicate multiplication, gives the result of the conversion you have asked for. The second line of output, which is marked with a ‘/’ to indicate division, gives the inverse of the conversion factor. If you convert 10 meters to feet, units will print

 
        * 32.808399
        / 0.03048

which tells you that 10 meters equals about 32.8 feet. The second number gives the conversion in the opposite direction. In this case, it tells you that 1 foot is equal to about 0.03 dekameters since the dekameter is 10 meters. It also tells you that 1/32.8 is about .03.

The units program prints the inverse because sometimes it is a more convenient number. In the example above, for example, the inverse value is an exact conversion: a foot is exactly .03048 dekameters. But the number given the other direction is inexact.

If you try to convert grains to pounds, you will see the following:

 
    You have: grains
    You want: pounds
            * 0.00014285714
            / 7000

From the second line of the output you can immediately see that a grain is equal to a seven thousandth of a pound. This is not so obvious from the first line of the output. If you find the output format confusing, try using the ‘--verbose’ option:

 
    You have: grain
    You want: aeginamina
            grain = 0.00010416667 aeginamina
            grain = (1 / 9600) aeginamina

If you request a conversion between units which measure reciprocal dimensions, then units will display the conversion results with an extra note indicating that reciprocal conversion has been done:

 
    You have: 6 ohms
    You want: siemens
            reciprocal conversion
            * 0.16666667
            / 6

Reciprocal conversion can be suppressed by using the ‘--strict’ option. As usual, use the ‘--verbose’ option to get more comprehensible output:

 
    You have: tex
    You want: typp
            reciprocal conversion
            1 / tex = 496.05465 typp
            1 / tex = (1 / 0.0020159069) typp

    You have: 20 mph
    You want: sec/mile
            reciprocal conversion
            1 / 20 mph = 180 sec/mile
            1 / 20 mph = (1 / 0.0055555556) sec/mile

If you enter incompatible unit types, the units program will print a message indicating that the units are not conformable and it will display the reduced form for each unit:

 
    You have: ergs/hour
    You want: fathoms kg^2 / day 
    conformability error
            2.7777778e-11 kg m^2 / sec^3
            2.1166667e-05 kg^2 m / sec

If you only want to find the reduced form or definition of a unit, simply press return at the ‘You want:’ prompt. Here is an example:

 
    You have: jansky
    You want: 
            Definition: fluxunit = 1e-26 W/m^2 Hz = 1e-26 kg / s^2

The output from units indicates that the jansky is defined to be equal to a fluxunit which in turn is defined to be a certain combination of watts, meters, and hertz. The fully reduced (and in this case somewhat more cryptic) form appears on the far right.

Some named units are treated as dimensionless in some situations. These include the radian and steradian. These units will be treated as equal to 1 in units conversions. Power is equal to torque times angular velocity. This conversion can only be performed if the radian is dimensionless.

 
    You have: (14 ft lbf) (12 radians/sec)
    You want: watts
            * 227.77742
            / 0.0043902509

Note that named dimensionaless units are not treated as dimensionless in other contexts. They cannot be used as exponents so for example, ‘meter^radian’ is not allowed.

If you want a list of options you can type ? at the ‘You want:’ prompt. The program will display a list of named units which are conformable with the unit that you entered at the ‘You have:’ prompt above. Note that conformable unit combinations will not appear on this list.

Typing help at either prompt displays a short help message. You can also type help followed by a unit name. This will invoke a pager on the units data base at the point where that unit is defined. You can read the definition and comments that may give more details or historical information about the unit.

Typing search text will display a list of all of the units whose names contain ‘text’ as a substring along with their definitions. This may help in the case where you aren’t sure of the right unit name.


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

3. Using units non-interactively

The units program can perform units conversions non-interactively from the command line. To do this, type the command, type the original units expression, and type the new units you want. You will probably need to protect the units expressions from interpretation by the shell using single quote characters.

If you type

 
    units '2 liters' 'quarts'

then units will print

 
        * 2.1133764
        / 0.47317647

and then exit. The output tells you that 2 liters is about 2.1 quarts, or alternatively that a quart is about 0.47 times 2 liters.

If the conversion is successful, then units will return success (0) to the calling environment. If units is given non-conformable units to convert, it will print a message giving the reduced form of each unit and it will return failure (nonzero) to the calling environment.

When units is invoked with only one argument, it will print out the definition of the specified unit. It will return failure if the unit is not defined and success if the unit is defined.


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

4. Unit expressions

In order to enter more complicated units or fractions, you will need to use operations such as powers, products and division. Powers of units can be specified using the ‘^’ character as shown in the following example, or by simple concatenation: ‘cm3’ is equivalent to ‘cm^3’. If the exponent is more than one digit, the ‘^’ is required. An exponent like ‘2^3^2’ is evaluated right to left. The ‘^’ operator has the second highest precedence. The ‘**’ operator is provided as an alternative exponent operator.

 
    You have: cm^3
    You want: gallons
            * 0.00026417205
            / 3785.4118

    You have: arabicfoot * arabictradepound * force
    You want: ft lbf  
            * 0.7296
            / 1.370614

Multiplication of units can be specified by using spaces, or an asterisk (‘*’). If units is invoked with the ‘--product’ option then the hyphen (‘-’) also acts as a multiplication operator. Division of units is indicated by the slash (‘/’) or by ‘per’.

 
    You have: furlongs per fortnight
    You want: m/s  
            * 0.00016630986
            / 6012.8727

Historically, multiplication in units was assigned a higher precedence than division. This disagrees with the usual precedence rules which give multiplication and division equal precedence, and it has been a source of confusion for people who think of units as a calculator.

By default, multiplication using the star (‘*’) now has the same precedence as division and hence follows the usual precedence rules. If units is invoked with the the ‘--oldstar’ option then then the old behavior is activated and ‘*’ will have the same precedence as the other multiplication operators described next.

Multiplication using a space or using the hyphen has a higher precedence than division and is evaluated left to right. So ‘m/s s/day’ is equivalent to ‘m / s s day’ and has dimensions of length per time cubed. Similarly, ‘1/2 meter’ refers to a unit of reciprocal length equivalent to .5/meter, which is probably not what you would intend if you entered that expression.

You can indicate division of numbers with the vertical dash (‘|’), so if you wanted half a meter you could write ‘1|2 meter’. This operator has the highest precedence so the square root of two thirds could be written ‘2|3^1|2’.

 
    You have: 1|2 inch
    You want: cm
            * 1.27
            / 0.78740157

Parentheses can be used for grouping as desired.

 
    You have: (1/2) kg / (kg/meter)
    You want: league
            * 0.00010356166
            / 9656.0833

Prefixes are defined separately from base units. In order to get centimeters, the units database defines ‘centi-’ and ‘c-’ as prefixes. Prefixes can appear alone with no unit following them. An exponent applies only to the immediately preceding unit and its prefix so that ‘cm^3’ or ‘centimeter^3’ refer to cubic centimeters but ‘centi*meter^3’ refers to hundredths of cubic meters. Only one prefix is permitted per unit, so ‘micromicrofarad’ will fail, but ‘micro*microfarad’ will work, as will ‘micro microfarad’..

For units, numbers are just another kind of unit. They can appear as many times as you like and in any order in a unit expression. For example, to find the volume of a box which is 2 ft by 3 ft by 12 ft in steres, you could do the following:

 
    You have: 2 ft 3 ft 12 ft
    You want: stere
            * 2.038813
            / 0.49048148
    
    You have: $ 5 / yard
    You want: cents / inch
            * 13.888889
            / 0.072

And the second example shows how the dollar sign in the units conversion can precede the five. Be careful: units will interpret ‘$5’ with no space as equivalent to dollars^5.

Outside of the SI system, it is often desirable to add values of different units together. You may also wish to use units as a calculator that keeps track of units. Sums of conformable units are written with the ‘+’ character.

 
    You have: 2 hours + 23 minutes + 32 seconds
    You want: seconds
            * 8612
            / 0.00011611705
    
    You have: 12 ft + 3 in
    You want: cm
            * 373.38
            / 0.0026782366
    You have: 2 btu + 450 ft lbf
    You want: btu
            * 2.5782804
            / 0.38785542

The expressions which are added together must reduce to identical expressions in primitive units, or an error message will be displayed:

 
    You have: 12 printerspoint + 4 heredium
                                          ^
    Illegal sum of non-conformable units

Historically ‘-’ has been used for products of units, which complicates its iterpretation in units. Because units provides several other ways to obtain unit products, and because ‘-’ is a subtraction operator in general algebraic expressions, units treats the binary ‘-’ as a subtraction operator by default. This behavior can be altered using the ‘--product’ option which causes units to treat the binary ‘-’ operator as a product operator. Note that when ‘-’ is a multiplication operator it has the same precedence as ‘*’, but when ‘-’ is a subtraction operator it has the lower precedence as the addition operator.

When ‘-’ is used as a unary operator it negates its operand. Regardless of the units options, if ‘-’ appears after ‘(’ or after ‘+’ then it will act as a negation operator. So you can always compute 20 degrees minus 12 minutes by entering ‘20 degrees + -12 arcmin’. You must use this construction when you define new units because you cannot know what options will be in force when your definition is processed.

The ‘+’ character sometimes appears in exponents like ‘3.43e+8’. This leads to an ambiguity in an expression like ‘3e+2 yC’. The unit ‘e’ is a small unit of charge, so this can be regarded as equivalent to ‘(3e+2) yC’ or ‘(3 e)+(2 yC)’. This ambiguity is resolved by always interpreting ‘+’ as part of an exponent if possible.

Several built in functions are provided: ‘sin’, ‘cos’, ‘tan’, ‘ln’, ‘log’, ‘log2’, ‘exp’, ‘acos’, ‘atan’ and ‘asin’. The ‘sin’, ‘cos’, and ‘tan’ functions require either a dimensionless argument or an argument with dimensions of angle.

 
    You have: sin(30 degrees)
    You want: 
            Definition: 0.5

    You have: sin(pi/2)
    You want:  
            Definition: 1

    You have: sin(3 kg)
                      ^
    Unit not dimensionless

The other functions on the list require dimensionless arguments. The inverse trigonometric functions return arguments with dimensions of angle.

If you wish to take roots of units, you may use the ‘sqrt’ or ‘cuberoot’ functions. These functions require that the argument have the appropriate root. Higher roots can be obtained by using fractional exponents:

 
    You have: sqrt(acre)
    You want: feet
            * 208.71074
            / 0.0047913202
    
    You have: (400 W/m^2 / stefanboltzmann)^(1/4)
    You have:
            Definition: 289.80882 K
    
    You have: cuberoot(hectare)
                              ^
    Unit not a root

[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

Temperature Conversion Example

Nonlinear units are represented using functional notation. They make possible nonlinear unit conversions such temperature. This is different from the linear units that convert temperature differences. Note the difference below. The absolute temperature conversions are handled by units starting with ‘temp’, and you must use functional notation. The temperature differences are done using units starting with ‘deg’ and they do not require functional notation.

 
    You have: tempF(45)
    You want: tempC
            7.2222222

    You have: 45 degF
    You want: degC
            * 25
            / 0.04

Think of ‘tempF(x)’ not as a function but as a notation which indicates that ‘x’ should have units of ‘tempF’ attached to it. See section Defining nonlinear units. The first conversion shows that if it’s 45 degrees Fahrehneit outside it’s 7.2 degrees Celsius. The second conversions indicates that a change of 45 degrees Fahrenheit corresponds to a change of 25 degrees Celsius.

Some other examples of nonlinears units are ring size and wire gauge. There are numerous different gauges and ring sizes. See the units database for more details. Note that wire gauges with multiple zeroes are signified using negative numbers where two zeroes is -1. Alternatively, you can use the synonyms ‘g00’, ‘g000’, and so on that are defined in the units database.

 
    You have: wiregauge(11)
    You want: inches
            * 0.090742002
            / 11.020255

    You have: brwiregauge(g00)
    You want: inches
            * 0.348
            / 2.8735632

    You have: 1 mm
    You want: wiregauge
            18.201919

[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

5. Invoking units

You invoke units like this:

 
    units [options] [from-unit [to-unit]]

If the from-unit and to-unit are omitted, then the program will use interactive prompts to determine which conversions to perform. See section Interacting with units. If both from-unit and to-unit are given, units will print the result of that single conversion and then exit. If only from-unit appears on the command line, units will display the definition of that unit and exit. Units specified on the command line will need to be quoted to protect them from shell interpretation and to group them into two arguments. See section Using units non-interactively.

The following options allow you to read in an alternative units file, check your units file, or change the output format:

-c
--check

Check that all units and prefixes defined in the units data file reduce to primitive units. Print a list of all units that cannot be reduced. Also display some other diagnostics about suspicious definitions in the units data file. Note that only definitions active in the current locale are checked.

--check-verbose

Like the ‘-check’ option, this option prints a list of units that cannot be reduced. But to help find unit definitions that cause endless loops, it lists the units as they are checked. If units hangs, then the last unit to be printed has a bad definition. Note that only definitions active in the current locale are checked.

-o format
--output-format format

Use the specified format for numeric output. Format is the same as that for the printf function in the ANSI C standard. For example, if you want more precision you might use ‘-o %.15g’.

-f filename
--file filename

Instruct units to load the units file filename. If filename is the empty string (‘-f ''’) then the default units file will be loaded. This enables you to load the default file plus a personal units file. Up to 25 units files may be specified on the command line. This option overrides the UNITSFILE environment variable.

-h
--help

Print out a summary of the options for units.

-m
--minus

Causes ‘-’ to be interpreted as a subtraction operator. This is usually the default behavior.

-p
--product

Causes ‘-’ to be interpreted as a multiplication operator when it has two operands. It will act as a negation operator when it has only one operand: ‘(-3)’. Note that by default ‘-’ is treated as a subtraction operator.

--oldstar

Causes ‘*’ to have the old style precedence, higher than the precedence of division so that ‘1/2*3’ will equal ‘1/6’.

--newstar

Forces ‘*’ to have the new (default) precedence which follows the usual rules of algebra: the precedence of ‘*’ is the same as the precedence of ‘/’, so that ‘1/2*3’ will equal ‘3/2’.

--compact

Give compact output featuring only the conversion factor. This turns off the ‘--verbose’ option.

-q
--quiet
--silent

Suppress prompting of the user for units and the display of statistics about the number of units loaded.

-s
--strict

Suppress conversion of units to their reciprocal units. For example, units will normally convert hertz to seconds because these units are reciprocals of each other. The strict option requires that units be strictly conformable to perform a conversion, and will give an error if you attempt to convert hertz to seconds.

-1
--one-line

Give only one line of output (the forward conversion). Do not print the reverse conversion. Note that if a reciprocal conversion is performed then units will still print the “reciprocal conversion” line.

-t
--terse

Give terse output when converting units. This option can be used when calling units from another program so that the output is easy to parse. This option has the combined effect of these options: ‘--strict’ ‘--quiet’ ‘--one-line’ ‘--compact’.

-v
--verbose

Give slightly more verbose output when converting units. When combined with the ‘-c’ option this gives the same effect as ‘--check-verbose’.

-V
--version

Print program version number, tell whether the readline library has been included, and give the location of the default units data file.


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

6. Unit definitions

The conversion information is read from a units data file which is called ‘units.dat’ and is probably located in the ‘/usr/local/share’ directory. If you invoke units with the ‘-V’ option, it will print the location of this file. The default file includes definitions for all familiar units, abbreviations and metric prefixes. It also includes many obscure or archaic units.

Many constants of nature are defined, including these:

 
pi          ratio of circumference to diameter
c           speed of light
e           charge on an electron
force       acceleration of gravity
mole        Avogadro's number
water       pressure per unit height of water
Hg          pressure per unit height of mercury
au          astronomical unit
k           Boltzman's constant
mu0         permeability of vacuum
epsilon0    permitivity of vacuum
G           Gravitational constant
mach        speed of sound

The database includes atomic masses for all of the elements and numerous other constants. Also included are the densities of various ingredients used in baking so that ‘2 cups flour_sifted’ can be converted to ‘grams’. This is not an exhaustive list. Consult the units data file to see the complete list, or to see the definitions that are used.

The unit ‘pound’ is a unit of mass. To get force, multiply by the force conversion unit ‘force’ or use the shorthand ‘lbf’. (Note that ‘g’ is already taken as the standard abbreviation for the gram.) The unit ‘ounce’ is also a unit of mass. The fluid ounce is ‘fluidounce’ or ‘floz’. British capacity units that differ from their US counterparts, such as the British Imperial gallon, are prefixed with ‘br’. Currency is prefixed with its country name: ‘belgiumfranc’, ‘britainpound’.

The US Survey foot, yard, and mile can be obtained by using the ‘US’ prefix. These units differ slightly from the international length units. They were in general use until 1959, and are still used for geographic surveys. The acre is officially defined in terms of the US Survey foot. If you want an acre defined according to the international foot, use ‘intacre’. The difference between these units is about 4 parts per million. The British also used a slightly different length measure before 1959. These can be obtained with the prefix ‘UK’.

When searching for a unit, if the specified string does not appear exactly as a unit name, then the units program will try to remove a trailing ‘s’ or a trailing ‘es’. If that fails, units will check for a prefix. All of the standard metric prefixes are defined.

To find out what units and prefixes are available, read the standard units data file.


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

7. Defining new units

All of the units and prefixes that units can convert are defined in the units data file. If you want to add your own units, you can supply your own file. You can also add your own units definitions in the ‘.units.dat’ file in your home directory. If this file exists it is read before the units data file. It will not be read if any units files are specified on the command line.

A unit is specified on a single line by giving its name and an equivalence. Comments start with a ‘#’ character, which can appear anywhere in a line. The backslash character (‘\’) acts as a continuation character if it appears as the last character on a line, making it possible to spread definitions out over several lines if desired. A file can be included by giving the command ‘!include’ followed by the file’s name. The file will be sought in the same directory as the parent file unless a full path is given.

Unit names must not contain any of the operator characters ‘+’, ‘-’, ‘*’, ‘/’, ‘|’, ‘^’ or the parentheses. They cannot begin with a digit or a decimal point (‘.’), nor can they end with a digit (except for zero). Be careful to define new units in terms of old ones so that a reduction leads to the primitive units, which are marked with ‘!’ characters. Dimensionless units are indicated by using the string ‘!dimensionless’ for the unit definition.

When adding new units, be sure to use the ‘-c’ option to check that the new units reduce properly. If you create a loop in the units definitions, then units will hang when invoked with the ‘-c’ options. You will need to use the ‘--check-verbose’ option which prints out each unit as it checks them. The program will still hang, but the last unit printed will be the unit which caused the infinite loop.

If you define any units which contain ‘+’ characters, carefully check them because the ‘-c’ option will not catch non-conformable sums. Be careful with the ‘-’ operator as well. When used as a binary operator, the ‘-’ character can perform addition or multiplication depending on the options used to invoke units. To ensure consistent behavior use ‘-’ only as a unary negation operator when writing units definitions. To multiply two units leave a space or use the ‘*’ operator with care, recalling that it has two possible precedence values and may require parentheses to ensure consistent behavior. To compute the difference of ‘foo’ and ‘bar’ write ‘foo+(-bar)’ or even ‘foo+-bar’.

Here is an example of a short units file that defines some basic units:

 
m       !               # The meter is a primitive unit
sec     !               # The second is a primitive unit
rad     !dimensionless  # A dimensionless primitive unit
micro-  1e-6            # Define a prefix
minute  60 sec          # A minute is 60 seconds
hour    60 min          # An hour is 60 minutes
inch    0.0254 m        # Inch defined in terms of meters
ft      12 inches       # The foot defined in terms of inches
mile    5280 ft         # And the mile

A unit which ends with a ‘-’ character is a prefix. If a prefix definition contains any ‘/’ characters, be sure they are protected by parentheses. If you define ‘half- 1/2’ then ‘halfmeter’ would be equivalent to ‘1 / 2 meter’.


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

8. Defining nonlinear units

Some units conversions of interest are nonlinear; for example, temperature conversions between the Fahrenheit and Celsius scales cannot be done by simply multiplying by conversions factors.

When you give a linear unit definition such as ‘inch 2.54 cm’ you are providing information that units uses to convert values in inches into primitive units of meters. For nonlinear units, you give a functional definition that provides the same information.

Nonlinear units are represented using a functional notation. It is best to regard this notation not as a function call but as a way of adding units to a number, much the same way that writing a linear unit name after a number adds units to that number. Internally, nonlinear units are defined by a pair of functions which convert to and from linear units in the data file, so that an eventual conversion to primitive units is possible.

Here is an example nonlinear unit definition:

 
tempF(x) [1;K] (x+(-32)) degF + stdtemp ; (tempF+(-stdtemp))/degF + 32

A nonlinear unit definition comprises a unit name, a dummy parameter name, two functions, and two corresponding units. The functions tell units how to convert to and from the new unit. In order to produce valid results, the arguments of these functions need to have the correct dimensions. To facilitate error checking, you may specify the dimensions.

The definition begins with the unit name followed immediately (with no spaces) by a ‘(’ character. In parentheses is the name of the parameter. Next is an optional specification of the units required by the functions in this definition. In the example above, the ‘tempF’ function requires an input argument conformable with ‘1’. For normal nonlinear units definitions the forward function will always take a dimensionless argument. The inverse function requires an input argument conformable with ‘K’. In general the inverse function will need units that match the quantity measured by your nonlinear unit. The sole purpose of the expression in brackets to enable units to perform error checking on function arguments.

Next the function definitions appear. In the example above, the ‘tempF’ function is defined by

 
    tempF(x) = (x+(-32)) degF + stdtemp

This gives a rule for converting ‘x’ in the units ‘tempF’ to linear units of absolute temperature, which makes it possible to convert from tempF to other units.

In order to make conversions to Fahrenheit possible, you must give a rule for the inverse conversions. The inverse will be ‘x(tempF)’ and its definition appears after a ‘;’ character. In our example, the inverse is

 
    x(tempF) = (tempF+(-stdtemp))/degF + 32

This inverse definition takes an absolute temperature as its argument and converts it to the Fahrenheit temperature. The inverse can be omitted by leaving out the ‘;’ character, but then conversions to the unit will be impossible. If the inverse is omitted then the ‘--check’ option will display a warning. It is up to you to calculate and enter the correct inverse function to obtain proper conversions. The ‘--check’ option tests the inverse at one point and print an error if it is not valid there, but this is not a guarantee that your inverse is correct.

If you wish to make synonyms for nonlinear units, you still need to define both the forward and inverse functions. Inverse functions can be obtained using the ‘~’ operator. So to create a synonym for ‘tempF’ you could write

 
    fahrenheit(x) [1;K] tempF(x); ~tempF(fahrenheit)

You may occasionally wish to define a function that operates on units. This can be done using a nonlinear unit definition. For example, the definition below provides conversion between radius and the area of a circle. Note that this definition requires a length as input and produces an area as output, as indicated by the specification in brackets.

 
    circlearea(r) [m;m^2] pi r^2 ; sqrt(circlearea/pi)

Sometimes you may be interested in a piecewise linear unit such as many wire gauges. Piecewise linear units can be defined by specifying conversions to linear units on a list of points. Conversion at other points will be done by linear interpolation. A partial definition of zinc gauge is

 
    zincgauge[in] 1 0.002, 10 0.02, 15 0.04, 19 0.06, 23 0.1

In this example, ‘zincgauge’ is the name of the piecewise linear unit. The definition of such a unit is indicated by the embedded ‘[’ character. After the bracket, you should indicate the units to be attached to the numbers in the table. No spaces can appear before the ‘]’ character, so a definition like ‘foo[kg meters]’ is illegal; instead write ‘foo[kg*meters]’. The definition of the unit consists of a list of pairs optionally separated by commas. This list defines a function for converting from the piecewise linear unit to linear units. The first item in each pair is the function argument; the second item is the value of the function at that argument (in the units specified in brackets). In this example, we define ‘zincgauge’ at five points. For example, we set ‘zincgauge(1)’ equal to ‘0.002 in’. Definitions like this may be more readable if written using continuation characters as

 
    zincgauge[in] \
         1 0.002  \
        10 0.02   \
        15 0.04   \
        19 0.06   \
        23 0.1

With the preceeding definition, the following conversion can be performed:

 
    You have: zincgauge(10)
    You want: in
        * 0.02
        / 50
    You have: .01 inch
    You want: zincgauge
        5

If you define a piecewise linear unit that is not strictly monotonic, then the inverse will not be well defined. If the inverse is requested for such a unit, units will return the smallest inverse. The ‘--check’ option will print a warning if a non-monotonic piecewise linear unit is encountered.


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

9. Localization

Some units have different values in different locations. The localization feature accomodates this by allowing the units database to specify region dependent definitions. A locale region in the units database begins with ‘!locale’ followed by the name of the locale. The leading ‘!’ must appear in the first column of the units database. The locale region is terminated by ‘!endlocale’. The following example shows how to define a couple units in a locale.

 
!locale en_GB
ton                     brton
gallon                  brgallon
!endlocale

The current locale is specified by the LOCALE environment variable. Note that the ‘-c’ option only checks the definitions which are active for the current locale.


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

10. Environment variables

The units programs uses the following environment variables.

LOCALE

Specifies the locale. The default is ‘en_US’. Sections of the units database are specific to certain locales.

PAGER

Specifies the pager to use for help and for displaying the conformable units. The help function browses the units database and calls the pager using the +nn syntax for specifying a line number. The default pager is more, but less, emacs, or vi are possible alternatives.

UNITSFILE

Specifies the units database file to use (instead of the default). This will be overridden by the ‘-f’ option. Note that you can only specify a single units database using this environment variable.


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

11. Readline support

If the readline package has been compiled in, then when units is used interactively, numerous command line editing features are available. To check if your version of units includes the readline, invoke the program with the ‘--version’ option.

For complete information about readline, consult the documentation for the readline package. Without any configuration, units will allow editing in the style of emacs. Of particular use with units are the completion commands.

If you type a few characters and then hit ‘ESC’ followed by the ? key then units will display a list of all the units which start with the characters typed. For example, if you type metr and then request completion, you will see something like this:

 
You have: metr
metre             metriccup         metrichorsepower  metrictenth
metretes          metricfifth       metricounce       metricton
metriccarat       metricgrain       metricquart       metricyarncount
You have: metr

If there is a unique way to complete a unitname, you can hit the tab key and units will provide the rest of the unit name. If units beeps, it means that there is no unique completion. Pressing the tab key a second time will print the list of all completions.


[ < ] [ > ]   [ << ] [ Up ] [ >> ]         [Top] [Contents] [Index] [ ? ]

Index

Jump to:   -  
A   C   D   E   F   I   L   M   N   P   R   S   T   U   V  
Index Entry Section

-
-1 (option for units)5. Invoking units
-c (option for units)5. Invoking units
--check (option for units)5. Invoking units
--check-verbose (option for units)5. Invoking units
--compact (option for units)5. Invoking units
-f (option for units)5. Invoking units
--file (option for units)5. Invoking units
-h (option for units)5. Invoking units
--help (option for units)5. Invoking units
-m (option for units)5. Invoking units
--minus (option for units)5. Invoking units
--newstar (option for units)5. Invoking units
-o (option for units)5. Invoking units
--oldstar (option for units)5. Invoking units
--one-line (option for units)5. Invoking units
--output-format (option for units)5. Invoking units
-p (option for units)5. Invoking units
--product (option for units)5. Invoking units
-q (option for units)5. Invoking units
--quiet (option for units)5. Invoking units
-s (option for units)5. Invoking units
--silent (option for units)5. Invoking units
--strict (option for units)5. Invoking units
-t (option for units)5. Invoking units
--terse (option for units)5. Invoking units
-v (option for units)5. Invoking units
-V (option for units)5. Invoking units
--verbose (option for units)5. Invoking units
--verbose-check (option for units)5. Invoking units
--version (option for units)5. Invoking units

A
addition of units4. Unit expressions

C
changing nonlinear unit definitions8. Defining nonlinear units
changing units definitions7. Defining new units
command line options5. Invoking units
command line unit conversion3. Using units non-interactively

D
defining nonlinear units8. Defining nonlinear units
defining units7. Defining new units
dimensionless units2. Interacting with units
dimensionless units7. Defining new units
division of numbers4. Unit expressions
division of units4. Unit expressions

E
environment variables10. Environment variables

F
fractions4. Unit expressions
functions of units8. Defining nonlinear units
functions, built in4. Unit expressions

I
include files7. Defining new units
incompatible units2. Interacting with units
interactive use2. Interacting with units
invoking units5. Invoking units

L
linear interpolation8. Defining nonlinear units
LOCALE environment variable10. Environment variables
localization9. Localization

M
multiplication of units4. Unit expressions

N
non-conformable units2. Interacting with units
non-interactive unit conversion3. Using units non-interactively
nonlinear unit conversions8. Defining nonlinear units
nonlinear units, redefinition of8. Defining nonlinear units

P
PAGER environment variable10. Environment variables
piecewise linear units8. Defining nonlinear units
powers4. Unit expressions
products4. Unit expressions

R
readline, use with units11. Readline support
reciprocal conversion2. Interacting with units
roots4. Unit expressions

S
square roots4. Unit expressions
strict conversion2. Interacting with units
sums of units4. Unit expressions

T
temperature conversionsTemperature Conversion Example

U
unit definitions6. Unit definitions
unit expressions4. Unit expressions
unit name completion11. Readline support
units functions8. Defining nonlinear units
units, piecewise linear8. Defining nonlinear units
units, redefinition of7. Defining new units
UNITSFILE environment variable10. Environment variables

V
verbose output2. Interacting with units
verbose output2. Interacting with units

Jump to:   -  
A   C   D   E   F   I   L   M   N   P   R   S   T   U   V  

[Top] [Contents] [Index] [ ? ]

Footnotes

(1)

But Fahrenheit to Celsius is linear, you insist. Not so. A transformation T is linear if T(x+y)=T(x)+T(y) and this fails for T(x)=ax+b. This transformation is affine, but not linear.


[Top] [Contents] [Index] [ ? ]

Table of Contents


[Top] [Contents] [Index] [ ? ]

About This Document

This document was generated by Build Daemon on June 20, 2012 using texi2html 1.82.

The buttons in the navigation panels have the following meaning:

Button Name Go to From 1.2.3 go to
[ < ] Back Previous section in reading order 1.2.2
[ > ] Forward Next section in reading order 1.2.4
[ << ] FastBack Beginning of this chapter or previous chapter 1
[ Up ] Up Up section 1.2
[ >> ] FastForward Next chapter 2
[Top] Top Cover (top) of document  
[Contents] Contents Table of contents  
[Index] Index Index  
[ ? ] About About (help)  

where the Example assumes that the current position is at Subsubsection One-Two-Three of a document of the following structure:


This document was generated by Build Daemon on June 20, 2012 using texi2html 1.82.